Micro PLC ONI. Expandable version. With built-in screen. 12 digital inputs (4 as 0-20mA, 4 as 0-10V, 4 as 60kHz), 6 relay outputs. RTC. SD card. RS485. ethernet. Supply voltage 24V DC

Product ID:
Main specifications
Voltage type of supply voltage | Постоянный (DC) |
Supply voltage DC, В | 20,4...28,8 |
Supply voltage AC 50 Hz, В | - |
Number of analogue outputs | 0 |
Number of analogue inputs | 8 |
Description
Explosion-proof LED lamps "Ex-DKU" belong to electrical equipment intended for use in hazardous areas of class 2 (according to GOST IEC 60079-10-1-2011) categories IIA, IIB and IIC and temperature classes T1, T2, T3 and T4, as well as equipment intended for use in zones hazardous for ignition of combustible dust 21 and 22 (according to GOST IEC 60079-10-2-2001) in accordance with the requirements of GOST IEC 60079-14-2013 and assigned explosion protection markings according to GOST R IEC 60079-0-2011.
Advantages
- Velcro clamps with a soft fastener are easy to mount and dismantle.
- Thanks to the design, the clamps can be used repeatedly.
- Made from high strength nylon.
- Eliminate the possibility of damage to copper and optical communication lines.

Design Features
Specifications
Voltage type of supply voltage | Постоянный (DC) |
Supply voltage DC, В | 20,4...28,8 |
Supply voltage AC 50 Hz, В | - |
Number of analogue outputs | 0 |
Number of analogue inputs | 8 |
Number of digital inputs | 12 |
Number of digital outputs | 6 |
With display | Да |
Number of HW-interfaces RS-232 | 1 |
Number of HW-interfaces RS-485 | 1 |
Number of HW-interfaces industrial Ethernet | 1 |
Supporting protocol for TCP/IP | Да |
Supporting protocol for MODBUS | Да |
Supporting protocol for PROFIBUS | Нет |
Supporting protocol for CAN | Нет |
Supporting protocol for KNX | Нет |
Radiostandard Bluetooth | Нет |
Radiostandard WLAN 802.11 | Нет |
Radiostandard GPRS | Нет |
Radiostandard GSM | Нет |
Supporting protocol for DeviceNet Safety | Нет |
Supporting protocol for SUCONET | Нет |
Supporting protocol for SERCOS | Нет |
Supporting protocol for EtherNet/IP | Да |
Height, мм | 90 |
Supporting protocol for PROFIsafe | Нет |
Supporting protocol for other bus systems | Да |
Front build in possible | Нет |
Radiostandard UMTS | Нет |
Number of relay outputs | 6 |
Supporting protocol for PROFINET IO | Нет |
Redundancy | Нет |
Supporting protocol for PROFINET CBA | Нет |
Supporting protocol for LON | Нет |
Max. number of addressable digital I/O-ports | 174 |
Explosion safety category for gas | Нет |
Appendant operation agent (Ex ia) | Нет |
Max. number of time switches | 0 |
Supporting protocol for ASI | Нет |
Supporting protocol for INTERBUS | Нет |
Rack-assembly possible | Нет |
Supporting protocol for Data-Highway | Нет |
Supporting protocol for SafetyBUS p | Нет |
Model | Модульный |
System accessory | Нет |
Max. number of addressable analogue I/O-ports | 102 |
Rail mounting possible | Да |
Appendant operation agent (Ex ib) | Нет |
With optical interface | Нет |
Supporting protocol for AS-Interface Safety at Work | Нет |
Explosion safety category for dust | Нет |
Memory size, кБайт | 8,192 |
Width, мм | 95 |
Depth, мм | 58 |
Supporting protocol for INTERBUS-Safety | Нет |
Supporting protocol for DeviceNet | Нет |
Suitable for safety functions | Нет |
Wall mounting/direct mounting | Да |
Additional program memory possible | Нет |
Supporting protocol for Foundation Fieldbus | Нет |
IO link master | Нет |
Documents
Passports
Software