Voltage relay (single-phase). Overvoltage function. 220V AC

Voltage relay (single-phase). Overvoltage function. 220V AC
Product ID:

Main specifications

Voltage measurement range 1, В180
Voltage measurement range 2, В260
Voltage type for actuatingПеременный (AC)
Nominal voltage, В220 AC
Rated control supply voltage Us at AC 50HZ, В220

Description

Optical patch cords are used to switch optical communication lines and connect them to network and measuring equipment. An optical patch cord is a fiber optic cable terminated with an optical connector, if the cable is terminated only on one side, this kind of patch cord is called a pigtail. For our patch cords and pigtails we use only the best Corning fiber, an important factor in the quality of the patch cord is also the quality of the connector and in our connectors we use only ferrules (Ferrule Connector) of Adamant japanese company.

The optical connecting cord is a patch cord terminated on different sides by means of different types of connectors. Just as the pigtail, a is single-mode and multi-mode are provided.

Design Features

Specifications

Voltage measurement range 1, В180
Voltage measurement range 2, В260
Voltage type for actuatingПеременный (AC)
Nominal voltage, В220 AC
Rated control supply voltage Us at AC 50HZ, В220
Nominal current of contact groups at AC-1, А10
Endurance of time, с(0,1÷10) ± 10%
Hysteresis, процентов3
Depth, мм64
Control error, процентов± 5
Burning positionЛюбое
Weight, кг0,059
Ambient temperature, °C+20...+55
Mounting methodDIN-рейка (стандарт) 35 мм
Max section of the single-core wire, мм²1х2,5
MaintainabilityНет
Three-phase under voltage possibleНет
Error of measurements, процентов±1
Height, мм90
Mechanical wear resistance, циклов10^7
Width, мм18
Indicator of presence of voltageЗелёный светодиод (Un)
Contains function DC-under voltageНет
Degree of protection of IP front panelIP40
Single-phase under voltage possibleДа
Indicator of operation of the relayКрасный светодиод (R)
Three-phase over voltage possibleНет
Degree of protection of the IP terminalIP20
Nominal voltage of contact group, В250 АС / 24 DC
Rated control supply voltage Us at DC, В-
Number of contacts as change-over contact1
Electric wear resistance, циклов10^6
Single-phase over voltage possibleДа
Over voltage category3
Max the section of multiveins of a cable with tips, мм²1х2,5
Min. adjustable delay-on energization time, с0.5
Range of frequency of supply voltage, Гц45...65
Contains function DC-over voltageНет
Pollution degree2
Contains function DC-voltage hysteresisНет

Documents

Compatible Products

Analogs