Current control relay. 0,5-5 A. 24-240V AC / 24V DC IEK

Current control relay. 0,5-5 A. 24-240V AC / 24V DC IEK
Product ID:

Main specifications

Current measurement range, А0,5...5
Voltage type for actuatingПеремен./постоян. (AC/DC)
Rated control supply voltage Us at AC 50HZ, В24...240
Rated control supply voltage Us at DC, В24
The number of groups of the switching contacts1

Description

Used for assembly of the floor switchboard on 3 apartments intended for reception and distribution of the electric power in residential and public buildings, and also for protection of the departing lines at overloads and short circuits. The welded metal body consists of three compartments: input-accounting, distribution, low-current equipment compartment. In the input-accounting and distribution compartments there are DIN-rails for fixing meters (according to the number of apartments). The distribution compartment is equipped with DIN-rails for group lines and rail for busbar N and PE. The compartment is equipped with an operational panel. Compartment low voltage equipment provided with perforated profiles for the laying of television and radio networks, telephone lines, networks, burglar alarms, intercoms, etc. To ensure fire safety between low-current and power compartments located the partition.

Design Features

Specifications

Current measurement range, А0,5...5
Voltage type for actuatingПеремен./постоян. (AC/DC)
Rated control supply voltage Us at AC 50HZ, В24...240
Rated control supply voltage Us at DC, В24
The number of groups of the switching contacts1
Number of contacts as change-over contact0
Nominal current of contact groups at AC-1, А10
Extreme values of admissions, процентов5
Burning positionЛюбое
Over voltage category3
Contains function DC-voltage over currentНет
Height, мм90
Ambient temperature, °C-20...55
Number of contacts as normally open contact0
Max. permitted delay-on energization time, с10
Number of contacts as normally closed contact0
Max the section of multiveins of a cable with tips, мм²1х2,5
Min. adjustable off-delay time, с-
Mechanical wear resistance, циклов10^7
Indicator of presence of voltageЗелёный светодиод (Un)
Single-phase over current possibleДа
Pollution degree2
Three-phase hysteresis possibleНет
Control error, процентов± 5
Electric wear resistance, циклов10^6
MaintainabilityНет
Degree of protection of the IP terminalIP20
Three-phase over current possibleНет
Range of frequency of supply voltage, Гц50/60 ± 0,2
Min. adjustable delay-on energization time, с0.1
Supply voltage, В24...240 В AC / 24 В
Hysteresis, процентов5
Single-phase hysteresis possibleДа
Indicator of operation of the relayКрасный светодиод (R)
Degree of protection of IP front panelIP40
Width, мм18
Max section of the single-core wire, мм²1х2,5
Mounting methodDIN-рейка (стандарт) 35 мм
Three-phase under current possibleНет
Deviation range of voltage supply, процентов-15...10
Weight, кг0,062
Single-phase under current possibleДа
Depth, мм64
Power consumptionAC 0,09...3 ВА / DC 0,05...1,5 Вт
Max. permitted off-delay time, с-
Nominal voltage of contact group, В250В АС /24 DC
Contains function DC-voltage under currentНет

Documents

Compatible Products

Analogs