Micro PLC ONI. Expandable version. With built-in screen. 12 digital inputs (4 as 0-20mA, 4 as 0-10V, 4 as 60kHz), 6 relay outputs. RTC. SD card. RS485. ethernet. Supply voltage 24V DC

Аналоги

Описание

Explosion-proof LED lamps "Ex-DKU" belong to electrical equipment intended for use in hazardous areas of class 2 (according to GOST IEC 60079-10-1-2011) categories IIA, IIB and IIC and temperature classes T1, T2, T3 and T4, as well as equipment intended for use in zones hazardous for ignition of combustible dust 21 and 22 (according to GOST IEC 60079-10-2-2001) in accordance with the requirements of GOST IEC 60079-14-2013 and assigned explosion protection markings according to GOST R IEC 60079-0-2011.

Преимущества

  • Velcro clamps with a soft fastener are easy to mount and dismantle.
  • Thanks to the design, the clamps can be used repeatedly.
  • Made from high strength nylon.
  • Eliminate the possibility of damage to copper and optical communication lines.
Micro PLC ONI. Expandable version. With built-in screen. 12 digital inputs (4 as 0-20mA, 4 as 0-10V, 4 as 60kHz), 6 relay outputs. RTC. SD card. RS485. ethernet. Supply voltage 24V DC

Особенности конструкции

Технические характеристики

Voltage type of supply voltageПостоянный (DC)
Supply voltage DC, В20,4...28,8
Supply voltage AC 50 Hz, В-
Number of analogue outputs0
Number of analogue inputs8
Number of digital inputs12
Number of digital outputs6
With displayДа
Number of HW-interfaces RS-2321
Number of HW-interfaces RS-4851
Number of HW-interfaces industrial Ethernet1
Supporting protocol for TCP/IPДа
Supporting protocol for MODBUSДа
Supporting protocol for PROFIBUSНет
Supporting protocol for CANНет
Supporting protocol for KNXНет
Radiostandard BluetoothНет
Radiostandard WLAN 802.11Нет
Radiostandard GPRSНет
Radiostandard GSMНет
Supporting protocol for DeviceNet SafetyНет
Supporting protocol for SUCONETНет
Explosion safety category for gasНет
Supporting protocol for ASIНет
Supporting protocol for INTERBUSНет
ModelМодульный
Rail mounting possibleДа
Supporting protocol for EtherNet/IPДа
Supporting protocol for other bus systemsДа
Front build in possibleНет
RedundancyНет
Supporting protocol for PROFINET CBAНет
Max. number of addressable digital I/O-ports174
Appendant operation agent (Ex ia)Нет
Max. number of time switches0
Supporting protocol for Data-HighwayНет
Rack-assembly possibleНет
System accessoryНет
Max. number of addressable analogue I/O-ports102
Appendant operation agent (Ex ib)Нет
With optical interfaceНет
Memory size, кБайт8,192
Width, мм95
Depth, мм58
Supporting protocol for INTERBUS-SafetyНет
Supporting protocol for DeviceNetНет
Supporting protocol for Foundation FieldbusНет
Supporting protocol for SERCOSНет
Height, мм90
Supporting protocol for PROFIsafeНет
Radiostandard UMTSНет
Number of relay outputs6
Supporting protocol for PROFINET IOНет
Supporting protocol for LONНет
Supporting protocol for SafetyBUS pНет
Explosion safety category for dustНет
Supporting protocol for AS-Interface Safety at WorkНет
Suitable for safety functionsНет
Wall mounting/direct mountingДа
Additional program memory possibleНет
IO link masterНет