Miniature circuit breaker VA47-29 2P 4A 4,5kA C IEK

Описание

Modular circuit breakers (MCB) VA47-29 with a breaking capacity of 6 kA protect the wiring connected to them from overload and short circuits, designed to protect distribution and group circuits having different loads: - electrical appliances, lighting – MCB with characteristic B, - motors with small starting currents (compressor, fan) – MCB with characteristic C, - motors with high starting currents (hoists, pumps) - MCB with characteristic D. Automatic switches VA47-29 with breaking capacity 6kA are recommended for use in input-distribution devices for residential and public buildings with normal load. They have a 6kA breaking capacity standard for most countries. Such MCBs are most often used at the present time.

Преимущества

  • Two types of protection against overloads and short circuit.
  • Complete set of supplementary devices with the possibility of simple independent installation:
  • – State contact KS47;
  • – State contact KSV47;
  • – Undervoltage trip RMM47;
  • – Low-voltage release RN47.
  • Improved arc suppression system: extended service life, increased resistance to short-circuit currents.
  • Contact position indicator.
  • Wide operating temperature range from –40 to +50° С.
  • Simultaneous connection by FORK bar and flexible conductor is possible for power supply distribution via upper terminals, as well as connection by PIN bar.
  • New ergonomic design of ON/OFF lever.
  • Notched terminal clamps reduce the heat loss and increase mechanical stability of the connection.
Miniature circuit breaker VA47-29 2P 4A 4,5kA C IEK

Особенности конструкции

Технические характеристики

Nominal rated current, А4.0
Nominal rated voltage, В400
Release characteristicC
Rated short-circuit breaking capacity EN 60898, кА4,5
Number of poles2
Voltage typeПеремен./постоян. (AC/DC)
Range of useПромышленное и бытовое
Degree of protection (IP)IP20
Power loss, Вт6.0
Mounting methodна DIN-рейку
Number of poles (total)2
Mounting rail type35x7.5
Current limiting class3
Power poles quantity2
Rated short-circuit breaking capacity Icn EN 60898 at 400 V, кА4.5
Type of electric connectionВинтовое соединение
Max. cross section incoming cable, мм²25
Rated surge voltage invariability, кВ4
Rated short-circuit breaking capacity Icn EN 60898 at 230 V, кА4.5
Additional equipment possibleДа
Release actuating time in short-circuit tm zone, с0,1
Width in number of modular spacings2
Suitable for motor safety switchДа
Frequency, Гц50
Ambient classУХЛ4
Nominal voltage DC, В≤ 48
Electromagnetic releaseДа
Electronic releaseНет
Built-in depth, мм73,6
Explosion protectionБез взрывозащиты
Residual releaseНет
Switch off techniqueТепловой, электромагнитный
Number of protected poles2
Thermal releaseДа