Miniature circuit breaker VA47-29 2P 6A 4,5kA C IEK

Miniature circuit breaker VA47-29 2P 6A 4,5kA C IEK
Артикул:

Основные характеристики

Nominal rated current, А6.0
Nominal rated voltage, В400
Release characteristicC
Rated short-circuit breaking capacity EN 60898, кА4,5
Number of poles2

Описание

These empty enclosures are excellent for mounting in rooms with high humidity level or prominently dusty areas: garages, basements etc. as well as for open air installation.

Преимущества

  • Two types of protection against overloads and short circuit.
  • Complete set of supplementary devices with the possibility of simple independent installation:
  • – State contact KS47;
  • – State contact KSV47;
  • – Undervoltage trip RMM47;
  • – Low-voltage release RN47.
  • Improved arc suppression system: extended service life, increased resistance to short-circuit currents.
  • Contact position indicator.
  • Wide operating temperature range from –40 to +50° С.
  • Simultaneous connection by FORK bar and flexible conductor is possible for power supply distribution via upper terminals, as well as connection by PIN bar.
  • New ergonomic design of ON/OFF lever.
  • Notched terminal clamps reduce the heat loss and increase mechanical stability of the connection.
Miniature circuit breaker VA47-29 2P 6A 4,5kA C IEK

Особенности конструкции

Технические характеристики

Nominal rated current, А6.0
Nominal rated voltage, В400
Release characteristicC
Rated short-circuit breaking capacity EN 60898, кА4,5
Number of poles2
Voltage typeПеремен./постоян. (AC/DC)
Range of useПромышленное и бытовое
Built-in depth, мм73,6
Rated surge voltage invariability, кВ4
Explosion protectionБез взрывозащиты
Rated short-circuit breaking capacity Icn EN 60898 at 230 V, кА4.5
Electronic releaseНет
Power loss, Вт6.0
Degree of protection (IP)IP20
Ambient classУХЛ4
Frequency, Гц50
Release actuating time in short-circuit tm zone, с0,1
Type of electric connectionВинтовое соединение
Nominal voltage DC, В≤ 48
Residual releaseНет
Number of poles (total)2
Current limiting class3
Mounting methodна DIN-рейку
Number of protected poles2
Suitable for motor safety switchДа
Width in number of modular spacings2
Power poles quantity2
Thermal releaseДа
Max. cross section incoming cable, мм²25
Electromagnetic releaseДа
Switch off techniqueТепловой, электромагнитный
Rated short-circuit breaking capacity Icn EN 60898 at 400 V, кА4.5
Mounting rail type35x7.5
Additional equipment possibleДа

Документация