Miniature circuit breaker VA47-29 4P 10A 4,5kA C IEK

Описание

PSttbe-1 heat-shrink sleeve is designed for connection of aluminum or copper conductors of cables with plastic, rubber and polyethylene insulation with armor or shield for voltage 1 kV: AVBbShv-1, VBbShv-1, AVVB-1, AVVBG-1, VVB-1, VVBG-1, APvBbShv-1, PvBbShv-1, VVGE, AVVGE, PvVGE, APvVGE, their equivalents and versions. The sleeves can be installed under ground (directly in the ground, in tunnels and channels) and outdoors (on trestles, cable trays, etc).

Преимущества

  • Two types of protection against overloads and short circuit.
  • Complete set of supplementary devices with the possibility of simple independent installation:
  • – State contact KS47;
  • – State contact KSV47;
  • – Undervoltage trip RMM47;
  • – Low-voltage release RN47.
  • Improved arc suppression system: extended service life, increased resistance to short-circuit currents.
  • Contact position indicator.
  • Wide operating temperature range from –40 to +50° С.
  • Simultaneous connection by FORK bar and flexible conductor is possible for power supply distribution via upper terminals, as well as connection by PIN bar.
  • New ergonomic design of ON/OFF lever.
  • Notched terminal clamps reduce the heat loss and increase mechanical stability of the connection.
Miniature circuit breaker VA47-29 4P 10A 4,5kA C IEK

Особенности конструкции

Технические характеристики

Nominal rated current, А10.0
Nominal rated voltage, В400
Release characteristicC
Rated short-circuit breaking capacity EN 60898, кА4,5
Number of poles4
Voltage typeПеремен./постоян. (AC/DC)
Range of useПромышленное и бытовое
Rated short-circuit breaking capacity Icn EN 60898 at 230 V, кА4.5
Width in number of modular spacings4
Power poles quantity4
Built-in depth, мм73,6
Max. cross section incoming cable, мм²25
Current limiting class3
Power loss, Вт12.0
Mounting rail type35x7.5
Frequency, Гц50
Number of protected poles4
Explosion protectionБез взрывозащиты
Type of electric connectionВинтовое соединение
Rated surge voltage invariability, кВ4
Number of poles (total)4
Rated short-circuit breaking capacity Icn EN 60898 at 400 V, кА4.5
Ambient classУХЛ4
Electromagnetic releaseДа
Electronic releaseНет
Residual releaseНет
Thermal releaseДа
Additional equipment possibleДа
Suitable for motor safety switchДа
Switch off techniqueТепловой, электромагнитный
Nominal voltage DC, В≤ 48
Release actuating time in short-circuit tm zone, с0,1
Mounting methodна DIN-рейку
Degree of protection (IP)IP20

Документация

Совместно применяемые изделия