ITK adapter cat.6 UTP type RJ45-RJ45

Advantages

  • Support for the SPODES protocol according to GOST R 58940-2020.
  • Compliance with industry requirements, including Decree of the Government of the Russian Federation of June 19, 2020 N 890 "On the procedure for providing access to the minimum set of functions of intelligent metering systems for electrical energy (power)".
  • Measurement of network parameters in real time:
  • - active and reactive electricity;
  • - active power for each phase and the total value in two directions;
  • - reactive power for each phase and the total value in two directions;
  • - total power for each phase and the total value in two directions;
  • - time-averaged power factor (cos φ);
  • - phase voltage for each phase and linear;
  • - current in each phase;
  • - current in the neutral wire;
  • - network frequency;
  • - imbalance of currents in the phase and neutral wires.
  • The data update interval for each measured parameter is no more than 0.5 s.
  • The error in measuring the parameters of the quality of electrical energy must correspond to class S or higher in accordance with GOST 30804.4.30-2013.
  • Frequency deviation (with specification in terms of the frequency measurement range from 47.5 to 52.5 Hz).
  • Possibility to configure the following settings:
  • - current date, time, calendar of weekends and holidays;
  • - start date of the billing period;
  • - number of effective tariffs and tariff schedule;
  • - composition and sequence of displaying messages and measured parameters on the display;
  • - threshold values ​​for fixing power supply quality violations;
  • - operation parameters of built-in switching devices;
  • - changing passwords and access control;
  • - transformation ratios for semi-indirect switching devices.
  • The ability to record the following events in the form of an event log generated in the internal non-volatile memory of the device:
  • - the fact of a change in the state of the device case opening contact;
  • - the fact of changing the state of the contact of the terminal cover (covers);
  • - access attempts in violation of access control rules;
  • - access attempts with unsuccessful identification and (or) authentication;
  • - attempts of unauthorized violation of software integrity;
  • - the fact of changing the device settings;
  • - the fact of the impact of a magnetic field with a value of the modulus of the magnetic induction vector over 150 mT;
  • - the fact of voltage deviation in the measuring circuits from the specified limits;
  • - the fact of absence or low voltage for each phase in the presence of current in the measuring circuits with configurable thresholds;
  • - the fact of the absence of voltage or the voltage value below the programmed threshold for each phase with the fixation of the time of loss and restoration of voltage;
  • - the fact of phase inversion or violation of the phase sequence;
  • - the fact of exceeding the ratio of the specified values ​​of consumption of active and reactive power (cos φ);
  • - the fact of exceeding the specified power limit;
  • - the fact of changing the direction of energy (power) flow;
  • - the fact and reason for switching on and off the built-in switching device;
  • - the fact of a successful or unsuccessful self-diagnosis procedure;
  • ...
ITK adapter cat.6 UTP type RJ45-RJ45

Design Features

Specifications

Connection 1Прочее
Connection type connection 1Вилка/штекер
Connection 2Прочее
Connection type connection 2Вилка/штекер
Cable length, м0.00
ScreenedНет
With terminal resistorНет
Category6
Max. amperage, А1.5
Voltage, В48
Material housingПластик
Ambient temperature, °C0...70
ColourБелый
DisplayUTP
Material of contactsБронза с позолотой

Documents

Analogs